Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type

Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type

$ 75.99
19 products sold in last 2 hours
Selling fast! Over 7 people have in their cart
Description PRODUCT DESCRIPTION Indicators of N24 series are destined for measurement of d.c. voltage or d.c. current, temperature from Pt100 sensors and J, K thermocouples, a.c. voltage and a.c. current. Thank to competitive price they are ideal solution for low-budget applications. Features: 4-digit LED display, digits of 20 mm high, Possible configuration of parameters through the PD14 programmer and the free delivered LPConfig program, precision of displayed results (decimal point), measurement averaging time, recounting of indications (individual characteristic), automatic or manual compensation: temperature of cold junction for measurements with thermocouples or wire resistance for Pt100 sensors (N24T), Supply: 85…253 V a.c./d.c. or 20…24 V a.c./d.c., 110 V a.c., 230 V a.c. Casing protection grade: IP65 Overall dimensions: 96 x 48 x 64 mm SPECIFICATIONS Model Measuring ranges Parameters Overloads Errors N24S N25S -11 mV..-10mV..60mV..66mV input resistance: >1MΩ Short duration overload (3s): 10 Un Sustained overload:10% Basic error (at manufacurer’s settings): ±(0.2% of range 1 digit) Additional error from ambient temperature changes: ±(50% of basic error/10K) -1V..0V..10V..11V -11V..-10V..10V..11V -1mA..0mA..20mA..22mA input resistance: 10Ω ±1% Short duration overload (3s): 10 In Sustained overload:10% 3.6 mA..4mA..20mA..22mA -22mA..-20mA..20mA..22mA input resistance: 5Ω ±1% N24T N25T Pt100 -50˚C..150˚C current flowing through the sensor <300 μA Resistance of wires connecting thermometer with meter: 10Ω (per wire) Short duration overload (3s) (input of sensors): 30V Basic error (at manufacturer’s settings): ±(0.2% of range 1 digit) Additional errors in rated operating conditions compensation of cold junction temperature changes: ±0.2% of range from ambient temperature changes: ±(50% of basic error/10K) -50˚C..400˚C Thermocouple J -50˚C..1200˚C   Thermocouple K -50˚C..1370˚C N24Z N25Z 1..100..120 V a.c. input resistance > 2MΩ Short duration overload (3s): 2 Un (<1000V) Sustained overload 20% Basic error (at manufacturer’s settings): voltage and current: ±(0.5% of range 1 digit) in frequency interval 20..500Hz frequency: ±(0.02% of range 1 digit) Additional error from ambienttemperature changes: ±(50% of basicerror/10K) 2,5..250..300 V a.c. 4..400..600 V a.c. 20..500 Hz (in voltage range: 24..480 V) 0.01..1..1.2 A a.c. input resistance: 50mΩ ±10% Short duration overload (3s): 10 In Sustained overload 20% 0,005..5..6 A a.c. input resistance: 10mΩ ±10% N24H N25H -1..50..55 V d.c. input resistance > 2MΩ Short duration overload (3s): 2 Un (<1000V) Sustained overload 10% Basic error (at manufacturer’s settings): ±(0.2% of range 1 digit) Additional error from ambient temperature changes: ±(50% of basic error/10K) -3..200..220 V d.c. -120..-100..100..120 V d.c. -300..-250..250..300 V d.c. -480..-400..400..480 V d.c. -0.1..1..1.1 A d.c. input resistance: 50mΩ ±10% Short duration overload (3s): 10 In Sustained overload 10% -1.2..-1..1..1.2 A d.c. -0.1..5..5.5 A d.c. input resistance: 10mΩ ±10% -6..-5..5..6 A d.c. Outputs Model Output Voltage For N24/ N25 S&T Output for supply external transducers 24V ± 5% 30 mA External features Weight <0,25 kg   Dimensions 96 x 48 x 64 mm   Protection level(acc. to EN 60529) ensured by the housing: IP65 from the terminal side: IP20 Display 4-digit LED display, 20 mm height, red colour 5-digit LED display, 14 mm height, red colour indication range: -1999..9999 indication range: -19999..99999 Rated operating conditions Supply voltage 230 V ± 10% a.c. (45..65 Hz); 110 V ± 10% a.c. (45..65 Hz) 110 V ± 10% a.c. (45..65 Hz); 85..253 V a.c. (45..65 Hz) or d.c.;20..40 V a.c. (45..65 Hz) or d.c. input power consumption: 6 VA Temperature ambient: -10..23..55 ˚C storage: -25..85 ˚C Relative humidity ≤ 95% condensation inadmissible Working position any   Preheating time 30 min   Averaging time ≥ 0,5 s 1 second set by default Safety and compatibility requirements Electromagnetic compatibility Noise immunity Noise emission acc. to EN 61000-6-2 acc. to EN 61000-6-4 Insulation between circuits basic ac c. to EN 61010-1 Pollution degree 2 Installation category III (for the 400V option – category II) Maximal phase-to-earth working voltage for the supply circuit: 300V for the measuring input: 600V – category II (300 V cat. II) for the programming input: 5V Altitude above sea level <2000 m  Connection Diagrams Fig. 1. Electrical connections of the N24S/ N25S meter Fig. 2. Electrical connections of the N24T/ N25T meter Thermocouple of J or K type Fig. 3. Connections of N24T/N25T measuring inputs Resistance thermometer in a two-wire system Resistance thermometer in a three-wire system Fig. 4. Electrical connections of N24/25B8H and N24H meters with the measurement of voltage and frequency Fig. 5. Electrical connections of N24/25B8H meters with the current measurement
21 people are viewing this right now
Compare
  • Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type - CIBIDAEVITARE.IT Estimated Delivery : Up to 4 business days
  • Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type - CIBIDAEVITARE.IT Free Shipping & Returns :
  • Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type - CIBIDAEVITARE.IT
  • Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type - CIBIDAEVITARE.IT
  • Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type - CIBIDAEVITARE.IT
  • Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type - CIBIDAEVITARE.IT
  • Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type - CIBIDAEVITARE.IT
  • Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type - CIBIDAEVITARE.IT
Guaranteed Safe And Secure Checkout